LED Stadium Flood Lights
LED Stadium Flood Lights
LED Stadium Flood Lights
LED Stadium Flood Lights
LED Stadium Flood Lights

LED Stadium Flood Lights

Compare Namkoo LED stadium flood lights in 100W, 150W, 250W and 400W options. Select the rating and beam arrangement from the area size, mounting height and lighting requirements. These fixtures can be considered for sports areas and other large outdoor spaces.

  • Adjustable Mounting Options: Adjustable brackets allow the fixture to be aimed for the planned layout.
  • Weatherproof Design: The listed ingress protection rating is IP65.
  • Customizable Options: Confirm colour temperature and beam options for the selected model.
Description
Technical Data
More Details
Contact Us Now
Description

Namkoo LED stadium floodlight enquiries should be based on the venue layout and required light levels. The FL27A reference below lists 100–200 W models. Confirm the selected optic, mounting height and photometric performance before using this range for sports or large-area lighting.

LED Stadium Flood Lights

FL27A Configuration Notes:

  1. Power Options: The model table lists 100 W, 120 W, 150 W and 200 W. Confirm any other wattage separately rather than treating it as the same configuration.

  2. Lighting Output: Request measured lumens and a photometric file for the selected CCT and optic. Uniform field illumination depends on the complete layout and aiming plan.

  3. Power Consumption: Compare input power at equivalent maintained light levels. Operating hours and dimming settings determine energy consumption and potential savings.

  4. Housing Assembly: The table lists die-cast aluminium and a PC lens. Confirm the actual assembly, impact rating and environmental limits for the selected model.

  5. Optic Choices: Listed distributions include 30°, 60°, 90° and Type II, III or IV. Select the optic for the target area and spill-light requirements.

  6. Bracket Positioning: Confirm the mounting interface and structural load, then set the bracket to the approved aiming angle and secure it as instructed.

  7. Enclosure Ratings: IP66/IK08 is listed for this range. Verify the model documentation and cable-entry installation for the site conditions.

  8. Controls and Colour: Specify colour temperature, optic and any dimming interface in the order. Confirm driver compatibility with the proposed controls.

LED Stadium Flood Lights LED Stadium Flood Lights

Parameter Model Reference
Model Options FL27A-100WS, FL27A-120WS, FL27A-150WS, FL27A-200WM
Input Power 100W, 120W, 150W, 200W
Input Voltage 100-277V
Power Factor >0.95
LED Package SMD3030
LED Count 192 (100W, 120W, 150W), 384 (200W)
LED Arrangement 24P8S (100W, 120W, 150W), 48P8S (200W)
Listed Efficacy >140 LM/W
CCT Range 3000-6500K
CRI >70
Enclosure Ratings IP66/IK08
Housing Dimensions 330x410x78 mm (100W, 120W, 150W), 431x525x79 mm (200W)
Optic Options 30°/60°/90° or Type II/III/IV; confirm model
Assembly Materials Die-cast aluminum lamp housing + PC lens
Ambient Range -30℃~+60℃
Humidity Range 10%~90%
Life / Warranty Reference >50,000 h; confirm warranty terms
Technical Data

Technical Selection

Namkoo FL27A Floodlight Range
The FL27A model table covers 100 W, 120 W, 150 W and 200 W variants. Evaluate the range using a site lighting calculation and the selected luminaire datasheet. Other wattages need a separate model reference and should not be assumed to share the same housing, optics or driver. 

LED Stadium Flood Lights

 

Configuration Checklist:

1. Input Power: Choose among the listed 100–200 W variants using required light levels, pole positions and photometric data. Confirm the final model in the quotation.

2. Output and CRI: Request tested lumens at the chosen CCT and CRI. The table lists efficacy above 140 lm/W and CRI above 70; verify values for the supplied model.

3. Operating Energy: Compare power and controls at equivalent illumination. Confirm switching or dimming modes for training, events or routine area use.

4. Housing Materials: The model reference lists die-cast aluminium with a PC lens. Check environmental and mechanical ratings against the installation conditions.

5. Light Distribution: Select 30°, 60°, 90° or the listed asymmetric distributions using a lighting layout. Beam width alone does not establish uniformity.

6. Mounting and Aiming: Confirm bracket fit, supporting-structure loads and access for maintenance. Aim each fixture according to the approved calculation.

7. Outdoor Protection: The table lists IP66/IK08. Verify enclosure ratings, cable-entry sealing and ambient limits for the actual model.

8. Ordering Details: State model, input voltage, CCT, optic and controls with your quantity. Ask Namkoo for the datasheet, photometric file and written supply terms.

Led Stadium Lamp

 

More Details

Namkoo FL27A Overview: The FL27A floodlight combines a die-cast aluminium housing with listed PC optics. Confirm the coating and enclosure ratings for the site, particularly in coastal or corrosive environments. Use the selected model data to assess thermal conditions, mounting and light distribution.

LED Stadium Flood Lights

Model Selection:

  • Listed Power Range: Choose 100, 120, 150 or 200 W from this model table; confirm other models separately.
  • Rated Performance: Compare tested output and input power at the required CCT, CRI and optical distribution.
  • Environmental Fit: Verify IP66/IK08, ambient limits and coating suitability for the installation.
  • Optical Options: Select the beam distribution and CCT before preparing the final lighting layout.

Project Uses:

  • Sports Areas: Assess maintained illumination, uniformity and glare for the intended training or competition level.
  • Industrial Yards: Review the work areas, mounting positions and operating conditions.
  • Public Outdoor Areas: Check spill light and coverage for parking areas, access routes and building exteriors.

Energy Assessment: Estimate consumption from the selected wattage, fixture quantity, operating hours and controls. Compare alternatives at equivalent maintained light levels.

Installation Review:

  • Coverage Calculation: Use the model photometric file to determine spacing and aiming for the target area.
  • Mounting Details: Confirm bracket dimensions, structural support and access for servicing.

Send Namkoo the site layout, pole heights and lighting targets for a configuration enquiry. Request the datasheet, photometric file and written supply terms for the selected FL27A model.

Contact Us Now

Request a Stadium Light Quote

LED Stadium Flood Lights Project Support

Design Support

Email Support

Lighting Solutions

Discuss Your Stadium Lighting Layout

LED Stadium Flood Lights

For stadium flood lighting, share the area dimensions, mast locations and required lighting levels. Include any glare, spill-light or operating-hour requirements. Namkoo can discuss the fixture options and photometric information needed for the design. Confirm quantities, aiming and mounting details before ordering.